0 |
PLEASE TURN OFF POWER |
1 |
TH PARITY ALARM |
2 |
TV PARITY ALARM |
3 |
TOO MANY DIGITS |
4 |
ADDRESS NOT FOUND |
5 |
NO DATA AFTER ADDRESS |
6 |
ILLEGAL USE OF NEGATIVE SIGN |
7 |
ILLEGAL USE OF DECIMAL POINT |
9 |
ILLEGAL ADDRESS INPUT |
10 |
IMPROPER G–CODE |
11 |
NO FEEDRATE COMMANDED |
14 |
CAN NOT COMMAND G95 (M series) |
14 |
ILLEGAL LEAD COMMAND (T series) |
15 |
TOO MANY AXES COMMANDED (M series) |
15 |
TOO MANY AXES COMMANDED (T series) |
20 |
OVER TOLERANCE OF RADIUS |
21 |
ILLEGAL PLANE AXIS COMMANDED |
22 |
NO CIRCLE RADIUS |
23 |
ILLEGAL RADIUS COMMAND (T series) |
25 |
CANNOT COMMAND F0 IN G02/G03 (M series) |
27 |
NO AXES COMMANDED IN G43/G44 (M series) |
28 |
ILLEGAL PLANE SELECT |
29 |
ILLEGAL OFFSET VALUE (M series) |
29 |
ILLEGAL OFFSET VALUE (T series) |
30 |
ILLEGAL OFFSET NUMBER (M series) |
30 |
ILLEGAL OFFSET NUMBER (T series) |
31 |
ILLEGAL P COMMAND IN G10 |
32 |
ILLEGAL OFFSET VALUE IN G10 |
33 |
NO SOLUTION AT CRC (M series) |
33 |
NO SOLUTION AT CRC (T series) |
34 |
NO CIRC ALLOWED IN ST–UP /EXT BLK (M series) |
34 |
NO CIRC ALLOWED IN ST–UP /EXT BLK (T series) |
35 |
CAN NOT COMMANDED G31 (T series) |
35 |
CAN NOT COMMANDED G39 (M series) |
36 |
CAN NOT COMMANDED G31 (M series) |
37 |
CAN NOT CHANGE PLANE IN CRC (M seires) |
37 |
CAN NOT CHANGE PLANE IN NRC (T seires) |
38 |
INTERFERENCE IN CIRCULAR BLOCK (M seires) |
38 |
INTERFERENCE IN CIRCULAR BLOCK (T series) |
39 |
CHF/CNR NOT ALLOWED IN NRC (T series) |
40 |
INTERFERENCE IN G90/G94 BLOCK (T series) |
41 |
INTERFERENCE IN CRC (M seires) |
41 |
INTERFERENCE IN NRC (T seires) |
42 |
G45/G48 NOT ALLOWED IN CRC (M series) |
44 |
G27–G30 NOT ALLOWED IN FIXED CYC (M series) |
45 |
ADDRESS Q NOT FOUND (G73/G83) (M series) |
46 |
ILLEGAL REFERENCE RETURN COMMAND |
47 |
ILLEGAL AXIS SELECT |
48 |
BASIC 3 AXIS NOT FOUND |
49 |
ILLEGAL OPERATION (G68/G69) (M series) |
50 |
CHF/CNR NOT ALLOWED IN THRD BLK (M series) |
50 |
CHF/CNR NOT ALLOWED IN THRD BLK(T series) |
51 |
MISSING MOVE AFTER CHF/CNR (M series) |
51 |
MISSING MOVE AFTER CHF/CNR (T series) |
52 |
CODE IS NOT G01 AFTER CHF/CNR (M series) |
52 |
CODE IS NOT G01 AFTER CHF/CNR (T series) |
53 |
TOO MANY ADDRESS COMMANDS (M series) |
53 |
TOO MANY ADDRESS COMMANDS (T seires) |
54 |
NO TAPER ALLOWED AFTER CHF/CNR (T series) |
55 |
MISSING MOVE VALUE IN CHF/CNR (M series) |
55 |
MISSING MOVE VALUE IN CHF/CNR (T series) |
56 |
NO END POINT & ANGLE IN CHF/CNR (T series) |
57 |
NO SOLUTION OF BLOCK END (T series) |
58 |
END POINT NOT FOUND (M series) |
58 |
END POINT NOT FOUND (T series) |
59 |
PROGRAM NUMBER NOT FOUND |
60 |
SEQUENCE NUMBER NOT FOUND |
61 |
ADDRESS P/Q NOT FOUND IN G70–G73 (T series) |
62 |
ILLEGAL COMMAND IN G71–G76 (T series) |
63 |
SEQUENCE NUMBER NOT FOUND (T series) |
64 |
SHAPE PROGRAM NOT MONOTONOUSLY (T series) |
65 |
ILLEGAL COMMAND IN G71–G73 (T series) |
66 |
IMPROPER G–CODE IN G71–G73 (T series) |
67 |
CAN NOT ERROR IN MDI MODE (T series) |
69 |
FORMAT ERROR IN G70–G73 (T series) |
70 |
NO PROGRAM SPACE IN MEMORY |
71 |
DATA NOT FOUND |
72 |
TOO MANY PROGRAMS |
73 |
PROGRAM NUMBER ALREADY IN |
74 |
ILLEGAL PROGRAM NUMBER |
75 |
PROTECT |
76 |
ADDRESS P NOT DEFINED |
77 |
SUB PROGRAM NESTING ERROR |
78 |
NUMBER NOT FOUND |
79 |
PROGRAM VERIFY ERROR |
80 |
G37 ARRIVAL SIGNAL NOT ASSERTED (M series) |
80 |
G37 ARRIVAL SIGNAL NOT ASSERTED (T series) |
81 |
OFFSET NUMBER NOT FOUND IN G37 (M series) |
81 |
OFFSET NUMBER NOT FOUND IN G37 (T series) |
82 |
H–CODE NOT ALLOWED IN G37 (M series) |
82 |
T–CODE NOT ALLOWED IN G37 (T series) |
83 |
ILLEGAL AXIS COMMAND IN G37 (M series) |
83 |
ILLEGAL AXIS COMMAND IN G37 (T series) |
85 |
COMMUNICATION ERROR |
86 |
DR SIGNAL OFF |
87 |
BUFFER OVERFLOW |
88 |
LAN FILE TRANS ERROR (CHANNEL–1) |
89 |
LAN FILE TRANS ERROR (CHANNEL–2) |
90 |
REFERENCE RETURN INCOMPLETE |
91 |
REFERENCE RETURN INCOMPLETE |
92 |
AXES NOT ON THE REFERENCE POINT |
94 |
P TYPE NOT ALLOWED (COORD CHG) |
95 |
P TYPE NOT ALLOWED (EXT OFS CHG) |
96 |
P TYPE NOT ALLOWED (WRK OFS CHG) |
97 |
P TYPE NOT ALLOWED (AUTO EXEC) |
98 |
G28 FOUND IN SEQUENCE RETURN |
99 |
MDI EXEC NOT ALLOWED AFT. SEARCH |